General Inspection Checklist
- No holes in walls and ceilings
- Fire extinguishers up-to-date (see chart below)
- These must be checked annually. The tags must reflect an inspection has been performed in the calendar year.
- Aisles and exits maintain 42" clearance at all times
- Electrical panels must have 48" clearance all around
- Exit lighting marked
- Fire exits must be lit with a clearly defined lighted exit sign with battery backup. These units are powered from house power and should stay on at all times.
- Maintain a well-thought-out (and probably documented) fire exit plan
- Flammable materials kept off site or in flammable materials locker
- Flammable materials include oil-based paint, alcohols, white gas, etc. We don't really have any flammable materials to speak of at Free Geek.
- Don't daisy chain power cords
- This means that 1 extension cord to 1 power strip is acceptable, but 2 extension cords linked or 2 power strips linked isn't acceptable.
- No exposed electrical wiring
Maintainance Logs
HVAC Filters
- Vendors
- Honke Heating, Gresham, 503-666-3725
- Fred Meyer
- True Value Hardware
- Filter Log
- Filters should be changed 2 times per year.
- HEPA Filter?
Location | Size | Date |
Unit One: Warehouse | 28X30 | missing |
Unit Two: Receiving | ??x?? | disabled |
Unit Three: Eval | 12X21 | need to replace |
Unit Four: Store | ??x?? | June 2004 |
Unit Five: Admin/Lab | ??x?? | ??? |
Unit Six: Classroom | ??x?? | ??? |
Unit Seven: Meeting Room | ??x?? | ??? |
Fire Extinguishers
- Vendor
- United Fire & Safety
- xxxxx N MLK Blvd.
- Portland, OR 972xx
- FE Log
- Inspection tags good for one year.
Location | Type | Inspection Date |
Lab/build | ABC | February 2006 (service) |
Kitchen (volunteer) | ABC | February 2006 (service) |
Kitchen (Staff) | ABC | August 2006 (new) |
Kens space (down stares) | ABC | NONE YET |
Evaluation | ABC | February 2006 (service) |
Recycling | ABC | Augest 2006 (New) |
HVAC UNIT INFO
units listed from north to south
- UNIT ONE [Warehouse]
- Located in the Warehouse, next to the door from Advanced Testing.
- Serves
- Thermostat is manual, on west side of a pillar, near the front, obscured by shelving.
- Model Day & Night Co. Model 394GAW060175
- Gas valves are located at the unit and at the meter.Gas line runs through Black Hole, then along back wall through Eval, Build, Back Stage, and out near rollup door. Facing meters, it is the one on the right.
- Electrical switch is at the unit. Fed from ?
- Info -Gas Unit with no Air Conditioning.
- UNIT TWO [Receiving]
- Located in the attic space above Receiving, with air conditioning condenser on roof.
- Serves
- Thermostat is programable, on west wall of Receiving.
- Model
- Gas
- Electric Furnace, fed from?
- Info - Currently disabled, (make an rt ticket)
- UNIT THREE [Evaluation]
- Located on ceiling above Eval.
- Serves
- Thermostat Programmable, located on East wall of Eval II.
- Model - Day & Night - 394GAW060175
- Gas
- Electric furnace, fed from panel on north wall of eval.
- Info - Air conditioning?
- UNIT FOUR [Store]
- Located above bathroom in Admin/Lab area.
- Serves
- Thermostat programable, located on north wall of Thrift Store.
- Model
- Gas?
- Electric
- Info - Has air conditioning.
- UNIT FIVE [Admin/Lab]
- Located On roof above Lab.
- Serves all of space from Reception to Build.
- Thermostat is programable, located on south wall of Lab. Honeywell TH800 Series File:VisionPro Owner manual.pdf
- Model -
- Gas runs accross roof, shut offs at unit and meter. Meter at south rollup door, is second to left,facing meters, same meter feeds other units. (will document which units later).
- Electric
- Info - Gas unit with air conditioning.
- UNIT SIX [Classroom]
- Located On roof above Store
- Serves
- Thermostat programable, located on north wall of the classroom near the door to Lab. Honeywell TH800 Series File:VisionPro Owner manual.pdf
- Model
- Gas shut off's at roof unit, and at south rollup door,meter second to left, facing meters, shared by other units (to be documented later).
- Electric
- Info - Gas unit with air conditioning
check drain above store
- UNIT SEVEN [Meeting Room]
- Located in Art Studio above Meeting Room.
- Serves
- Thermostat manual, located on west wall in Library, next to Meeting Room door.
- Model
- Gas
- Electric? with air conditioning. Condenser located on roof? (need art stuff moved to access unit to clarify)
- Info -
THERMOSTATS
- Locations listed in Unit Info above.
- Batteries in programable thermostats should be changed annually
- Month ?
- Two AA batteries each?
PGE METER INFORMATION
(Listed from left to right when facing meters)
- Meter One, key P-A, account# ends in 7, Service Address: 1711 SE 10th Ave
- Meter Two, key P-A, account# ends in 5, Service Address: 1711 SE 10th Ave (2)
- Meter Three, Key P-A, account# ends in 3, Service Address: 1731 SE 10th Ave
- Meter Four, key P-A, account# ends in 1, Service Address: 1735 SE 10th Ave
- Meter Five, key P-B, account# ends in 9, Service Address: 1741 SE 10th Ave
- Meter Six, key P-B, services north upstairs tenants