Difference between revisions of "Server Build Checklist"

From FreekiWiki
Jump to navigation Jump to search
(→‎Diagnostics & Databases: more printme notes, write down ram config on sticker during build)
Line 1: Line 1:
 
==Preliminaries==
 
==Preliminaries==
* Check the motherboard for blown caps,
+
'''Check for blown caps''' - Examine all of the capacitors<br>
* Confirm that the battery (CMOS) is at least 3 volts,
+
'''Check battery''' - Confirm that the CMOS battery is at least 3 volts<br>
* Check that it boots without keyboard. "Keyboard failure" error is ok. Just be sure you're not prompted to "press key X to continue..."
+
'''Boot Process''' - Ensure that the server boots properly in the following ways:<br>
* Check that it boots from CD,
+
*'''Boots from CD''' - use an Ubuntu Live CD, leave Ubuntu running for next step<br>
* Check that it automatically boots after power loss,
+
*'''Boots automatically after power loss''' - while still in Ubuntu from the previous step, unplug all power cords (and the keyboard for the next step) from the server to simulate a sudden power loss. It should reboot automatically - if not, check BIOS settings.<br>
* '''Build Only:''' Boot to network and install Debian Squeeze to local disks,
+
*'''Boots without keyboard''' - the server may report a "Keyboard failure" error - this is okay as long it boots successfully without human intervention, such as "press key X to continue..."<br>
** Debian Wiki Guide to Software RAIDs: http://wiki.debian.org/DebianInstaller/SoftwareRaidRoot
 
** 2-3 disks
 
*** small (400-500M) raid1 with number of devices equal to number of disks
 
*** large raid1 with number of devices equal to number of disks
 
** 4+ disks
 
*** small raid1 (400-500M) with number of devices equal to number of disks
 
*** large raid6 with number of devices equal to number of disks
 
** LVM (configure larger raid1 or raid6 array as LVM volume)
 
*** volume (4G) named root (mounted at /, ext3 filesystem)
 
*** volume (1G) named swap (use as swap)
 
*** volume (remaining) named srv (mounted at /srv, ext3 filesystem)
 
  
** Wikipedia RAID article: http://en.wikipedia.org/wiki/RAID
+
 
 +
==='''RAID & LVM Setup  (Build ONLY)'''===
 +
 
 +
'''Install Debian Squeeze''' - Boot to network and install Debian Squeeze to local disks, choose hostname, leave domain name as “fglan”<br>
 +
===='''Setup Software RAID'''====
 +
*Debian Wiki Guide to Software RAIDs: http://wiki.debian.org/DebianInstaller/SoftwareRaidRoot
 +
'''Partition Disks:'''
 +
*Create small partition (400-500M) on each device
 +
**primary partition at the beginning of the drive
 +
**use as “physical volume for RAID”
 +
**set as bootable
 +
*Create large partition (all remaining space) on each device
 +
**primary, not bootable
 +
'''Setup RAID for small partitions:''' RAID1 (bootable) with the number of devices equal to number of disks<br>
 +
'''Setup RAID for large partitions:'''
 +
*'''For 2-3 disks:'''Setup RAID1, with number of devices equal to number of disks
 +
*'''For 4+ disks:'''Setup RAID6, with number of devices equal to number of disks
 +
 
 +
'''Configure LVM''' - configure larger RAID1 or RAID6 array as LVM volume
 +
*Create Logical Volume Group with same name as hostname
 +
*Select Large RAID array as LVM Volume
 +
**create volume (4G) named root (mounted at /, ext3 filesystem)
 +
**create volume (1G) named swap (use as swap)
 +
**create volume (remaining) named srv (mounted at /srv, ext3 filesystem)
 +
*Wikipedia RAID article: http://en.wikipedia.org/wiki/RAID
  
 
==Diagnostics & Databases==
 
==Diagnostics & Databases==

Revision as of 12:04, 16 May 2012

Preliminaries

Check for blown caps - Examine all of the capacitors
Check battery - Confirm that the CMOS battery is at least 3 volts
Boot Process - Ensure that the server boots properly in the following ways:

  • Boots from CD - use an Ubuntu Live CD, leave Ubuntu running for next step
  • Boots automatically after power loss - while still in Ubuntu from the previous step, unplug all power cords (and the keyboard for the next step) from the server to simulate a sudden power loss. It should reboot automatically - if not, check BIOS settings.
  • Boots without keyboard - the server may report a "Keyboard failure" error - this is okay as long it boots successfully without human intervention, such as "press key X to continue..."


RAID & LVM Setup (Build ONLY)

Install Debian Squeeze - Boot to network and install Debian Squeeze to local disks, choose hostname, leave domain name as “fglan”

Setup Software RAID

Partition Disks:

  • Create small partition (400-500M) on each device
    • primary partition at the beginning of the drive
    • use as “physical volume for RAID”
    • set as bootable
  • Create large partition (all remaining space) on each device
    • primary, not bootable

Setup RAID for small partitions: RAID1 (bootable) with the number of devices equal to number of disks
Setup RAID for large partitions:

  • For 2-3 disks:Setup RAID1, with number of devices equal to number of disks
  • For 4+ disks:Setup RAID6, with number of devices equal to number of disks

Configure LVM - configure larger RAID1 or RAID6 array as LVM volume

  • Create Logical Volume Group with same name as hostname
  • Select Large RAID array as LVM Volume
    • create volume (4G) named root (mounted at /, ext3 filesystem)
    • create volume (1G) named swap (use as swap)
    • create volume (remaining) named srv (mounted at /srv, ext3 filesystem)
  • Wikipedia RAID article: http://en.wikipedia.org/wiki/RAID

Diagnostics & Databases

  • Confirm that the server can boot from the local disk(s),
  • Test any USB ports (front and back),
  • Test the video ports (front and back),
  • Test network ports (at terminal: ifconfig eth0 up,ifconfig eth1 up, then tail -f /var/log/syslog, and when you plug and unplug the ethernet cable, you should see reasonable printouts. Ctrl-C to stop the tail command.),
  • QC Only: Remove any SATA/SAS drives and give them to your Instructor,
  • Run printme:
    • Boot from network,
    • Select printme from the network boot menu,
    • Log in as guest,
    • Open a terminal,
    • Run printme,
    • Record whether it's Tower or Rackmount and its size (1U, 2U, 3U, etc.), multiple power supplies, if it's using hardware raid, and anything else noteworthy.
  • Fill out the Server Specs sticker based on whether you are doing Build or QC:
    • BUILD:
      • Put System ID on server specs sticker,
      • Processor speed (GHz) and type (Xeon, Opteron),
      • Number of physical processors and number of cores per processor,
      • Number and type (DDR, DDR2) of RAM slots,
      • Number of RAM sticks with their type, speed, and size,
      • Number of hard drive bays and their interfaces (IDE, SCSI, SATA),
      • Do not print! Instead, put your Volunteer ID on a piece of tape on the system.
    • QC:
      • Confirm the accuracy of information already on the Specs sticker,
      • The total amount of installed RAM,
      • The number, type, and size of installed hard drives (IDE & SCSI only),
      • Print the printme, and tape it to the top of the system.
  • Have your Instructor look over the printme,
  • Move the system to the Server Build KVM and run Memtest, if it hasn't already been done.