Server Build Checklist

From FreekiWiki
Revision as of 15:04, 23 March 2011 by Scellef (talk | contribs)
Jump to navigation Jump to search
  • Check the motherboard for blown caps,
  • Confirm that the battery (CMOS) is at least 3 volts,
  • Check that it boots without keyboard,
  • Check that it boots from CD,
  • Check that it automatically boots after power loss,
  • Boot to network and install Debian Squeeze to local disks,
    • TODO: RAID Tutorial
  • Confirm that the server can boot from the local disk(s),
  • Test any USB ports (front and back),
  • Test the video ports (front and back),
  • Run printme:
    • Boot from network,
    • Select printme from the network boot menu,
    • Log in as guest,
    • Open a terminal (Shortcut: Ctrl + Alt + T),
    • Run printme,
    • Record whether it's Tower or Rackmount and its size (1U, 2U, 3U, etc.), and anything else noteworthy.
  • Fill out the Server Specs sticker:
    • Put System ID on server specs sticker,
    • Processor speed (GHz) and type (Xeon, Opteron),
    • Number of physical processors and number of cores per processor,
    • Number and type (DDR, DDR2) of RAM slots,
    • Number, size (MB or GB), and type (i.e. PC2100 ECC Registered) of individual ram sticks,
    • Total ram included (e.g. 6GB),
    • Number of hard drive bays and types of hard drive ports (IDE, SATA, SCSI).
  • Have your Instructor look over the printme,
  • Move the system to the Server Build KVM and run Memtest.