=Server Quality Control Checklist=
 
=Server Quality Control Checklist=
  
* check for blown caps
+
* Check the motherboard for blown caps,
* check battery (should be at least 3 volts)
+
* Confirm that the battery (CMOS) is at least 3 volts,
* check that it boots without keyboard
+
* Confirm that it boots without keyboard,
* check that the server can boot from the local disk(s)
+
* Confirm that the server can boot from the local disk(s),
* remove SATA (but not IDE or SCSI) drives
+
* Remove SATA (but not IDE or SCSI) drives,
* check that it boots from CD
+
* Check that it boots from CD,
* check that it automatically boots after power loss
+
* Check that it automatically boots after power loss,
* test USB ports (front and back)
+
* Test any USB ports (front and back),
* test video ports (front and back)
+
* Test the video ports (front and back),
* run printme
+
* Run printme:
** boot from network
+
** Boot from network,
** select fat client (printme)
+
** Select fat client (printme),
** click log in as guest
+
** Log in as guest,
** open a terminal
+
** Open a terminal (Shortcut: Ctrl + Alt + T),
** run printme
+
** Run printme,
** put tower or rackmount and size (1U, 2U, 3U, 4U, etc.) in printme notes
+
** Record whether it's Tower or Rackmount and its size (1U, 2U, 3U, etc.), the RAM size and speed, and anything else noteworthy.
* ensure server specs label contains accurate information:
+
* Ensure server specs label contains accurate information:
** put system id on server specs sticker
+
** Put System ID on server specs sticker,
** processor speed (GHz) and type (Xeon, Opteron)
+
** Processor speed (GHz) and type (Xeon, Opteron),
** number of physical processors and number of cores per processor
+
** Number of physical processors and number of cores per processor,
** number and type (DDR, DDR2) of ram slots
+
** Number and type (DDR, DDR2) of ram slots,
** number, size (MB or GB), and type (i.e. PC2100 ECC Registered) of individual ram sticks
+
** Number, size (MB or GB), and type (i.e. PC2100 ECC Registered) of individual ram sticks,
** total ram included (i.e. 6GB)
+
** Total ram included (i.e. 6GB),
** number of hard drive bays
+
** Number of hard drive bays,
** types of hard drive ports (ide, sata, scsi)
+
** types of hard drive ports (IDE, SATA, SCSI).
  
 
<noinclude>[[Category:Server_Build]]</noinclude>
 
<noinclude>[[Category:Server_Build]]</noinclude>

Revision as of 13:50, 23 March 2011

Server Quality Control Checklist

  • Check the motherboard for blown caps,
  • Confirm that the battery (CMOS) is at least 3 volts,
  • Confirm that it boots without keyboard,
  • Confirm that the server can boot from the local disk(s),
  • Remove SATA (but not IDE or SCSI) drives,
  • Check that it boots from CD,
  • Check that it automatically boots after power loss,
  • Test any USB ports (front and back),
  • Test the video ports (front and back),
  • Run printme:
    • Boot from network,
    • Select fat client (printme),
    • Log in as guest,
    • Open a terminal (Shortcut: Ctrl + Alt + T),
    • Run printme,
    • Record whether it's Tower or Rackmount and its size (1U, 2U, 3U, etc.), the RAM size and speed, and anything else noteworthy.
  • Ensure server specs label contains accurate information:
    • Put System ID on server specs sticker,
    • Processor speed (GHz) and type (Xeon, Opteron),
    • Number of physical processors and number of cores per processor,
    • Number and type (DDR, DDR2) of ram slots,
    • Number, size (MB or GB), and type (i.e. PC2100 ECC Registered) of individual ram sticks,
    • Total ram included (i.e. 6GB),
    • Number of hard drive bays,
    • types of hard drive ports (IDE, SATA, SCSI).