Difference between revisions of "Legacy Evaluation Overview"

From FreekiWiki
Jump to navigation Jump to search
(→‎AMD K6/2: - update)
Line 33: Line 33:
  
 
=== AMD K6/2 ===
 
=== AMD K6/2 ===
* All major case parts required
+
* Ensure all major case parts are present (i.e. side and front panel)
* replace hard drive with prewiped 6 gig drives
+
* Replace hard drive(s) with a single, pre-wiped 6 gig drive
* make sure it sees the drive
+
* Power up the system and ensure it recognizes the hard drive during startup
*:''make sure pulled drives are put into storage quickly''
+
* Quickly place pulled hard drives into storage
*Things to remove:
+
***:''Storage for pulled hard drives is located between System Eval 1 and System Eval 2''
**All nonpropriatary cards - except video
+
 
 +
*Things to remove from AMD K6/2 keeper systems:
 +
**All nonproprietary cards (AGP, PCI, ISA, etc) '''''except the video card'''''
 
**All loose cables
 
**All loose cables
**cddrives over 40x on the faceplate
+
**CD-ROM drives marked 40x or higher on the faceplate
**cdrw and dvd drives
+
**All CD-RW and DVD-ROM/RW drives
 +
<br/>
 +
''** NOTE: We should consider placing a whiteboard in Legacy Evaluation where we can list additional instructions that are subject to change, such as when to pull the following items not listed above:''
 +
** Tape drives
 +
** ZIP drives
 +
** Floppy drives
  
 
=== 386 486 P ===
 
=== 386 486 P ===

Revision as of 13:39, 20 January 2007

This is a graph with borders and nodes. Maybe there is an Imagemap used so the nodes may be linking to some Pages.

Priorities for legacy systems

if the computer does not fit the criteria on this page that is a reason for recycling it
The Priority is top to bottom

AMD K6/2

  • Ensure all major case parts are present (i.e. side and front panel)
  • Replace hard drive(s) with a single, pre-wiped 6 gig drive
  • Power up the system and ensure it recognizes the hard drive during startup
  • Quickly place pulled hard drives into storage
      • Storage for pulled hard drives is located between System Eval 1 and System Eval 2
  • Things to remove from AMD K6/2 keeper systems:
    • All nonproprietary cards (AGP, PCI, ISA, etc) except the video card
    • All loose cables
    • CD-ROM drives marked 40x or higher on the faceplate
    • All CD-RW and DVD-ROM/RW drives


** NOTE: We should consider placing a whiteboard in Legacy Evaluation where we can list additional instructions that are subject to change, such as when to pull the following items not listed above:

    • Tape drives
    • ZIP drives
    • Floppy drives

386 486 P

  • recycle if case is missing parts or dirty
  • recycle if missing hard drive, video output, power supply, etc...
  • run badblocks on all the drives
    badblocks -wvv /dev/hd*


Incompatibles

  • Amiga
  • Apple, etc:
    • Mac
    • Radius
    • PowerPC
    • PowerComputing
  • Commodore
  • DEC (Digital Equipment Corporation)
  • Sun
  • Silicon Graphics (SGI)
    • Indy (they're blue)