Difference between revisions of "Server Build Checklist"

From FreekiWiki
Jump to navigation Jump to search
Line 2: Line 2:
 
* Check the motherboard for blown caps,
 
* Check the motherboard for blown caps,
 
* Confirm that the battery (CMOS) is at least 3 volts,
 
* Confirm that the battery (CMOS) is at least 3 volts,
* Check that it boots without keyboard,
+
* Check that it boots without keyboard. "Keyboard failure" error is ok. Just be sure you're not prompted to "press key X to continue..."
 
* Check that it boots from CD,
 
* Check that it boots from CD,
 
* Check that it automatically boots after power loss,
 
* Check that it automatically boots after power loss,
Line 8: Line 8:
 
** Debian Wiki Guide to Software RAIDs: http://wiki.debian.org/DebianInstaller/SoftwareRaidRoot
 
** Debian Wiki Guide to Software RAIDs: http://wiki.debian.org/DebianInstaller/SoftwareRaidRoot
 
** Wikipedia RAID article: http://en.wikipedia.org/wiki/RAID
 
** Wikipedia RAID article: http://en.wikipedia.org/wiki/RAID
 +
 
==Diagnostics & Databases==
 
==Diagnostics & Databases==
 
* Confirm that the server can boot from the local disk(s),
 
* Confirm that the server can boot from the local disk(s),

Revision as of 15:09, 30 June 2011

Preliminaries

  • Check the motherboard for blown caps,
  • Confirm that the battery (CMOS) is at least 3 volts,
  • Check that it boots without keyboard. "Keyboard failure" error is ok. Just be sure you're not prompted to "press key X to continue..."
  • Check that it boots from CD,
  • Check that it automatically boots after power loss,
  • Build Only: Boot to network and install Debian Squeeze to local disks,

Diagnostics & Databases

  • Confirm that the server can boot from the local disk(s),
  • Test any USB ports (front and back),
  • Test the video ports (front and back),
  • QC Only: Remove any SATA drives and give them to your Instructor,
  • Run printme:
    • Boot from network,
    • Select printme from the network boot menu,
    • Log in as guest,
    • Open a terminal,
    • Run printme,
    • Record whether it's Tower or Rackmount and its size (1U, 2U, 3U, etc.), and anything else noteworthy.
  • Fill out the Server Specs sticker based on whether you are doing Build or QC:
    • BUILD:
      • Put System ID on server specs sticker,
      • Processor speed (GHz) and type (Xeon, Opteron),
      • Number of physical processors and number of cores per processor,
      • Number and type (DDR, DDR2) of RAM slots,
      • Number of hard drive bays and their interfaces (IDE, SCSI, SATA),
      • Do not print! Instead, put your Volunteer ID on a piece of tape on the system.
    • QC:
      • Confirm the accuracy of information already on the Specs sticker,
      • Number of RAM sticks with their type, speed, and size,
      • The total amount of installed RAM,
      • The number, type, and size of installed hard drives (IDE & SCSI only),
      • Print the printme, and tape it to the top of the system.
  • Have your Instructor look over the printme,
  • Move the system to the Server Build KVM and run Memtest, if it hasn't already been done.
  • Consult your Instructor for a new project!